HP 8145A with Option 023, Optical Time Domain Reflectometer (OTDR).
Specifications at glance for the 8154A with option 023
- Wavelength: 1300 nm +/- 30 nm and 1540 nm +/-30 nm
- Dynamic Range one way backscatter: 28/26 dB
- Fresnel Reflection (4%): 42/40 dB
- Measurement time at 1300 nm: 22 dB after 10 sec, 16 dB after 1 sec
- Pulsewidth: 125/250/500 ns 1/2/4/8 us
- HP-IB Capability
- RS-232 optional, not always included
One opitcal interface connector is needed. It is not included. Please select one from the below list
- 81000KI: SC/P
- 81000FI: FC/PC
- 81000LI: LC/PC
- 81000VI: SC/PC